CHM5
Bolted two-stage heat exchanger designed for cooling wort from 98°C to 7°C using 15°C and 1°C water. Wort cooler is positioned and attached to a stainless steel panel on which are placed operating and control elements of the cooler. Wort aeration -O2 is also a part of the complete system.
Temperature sensors allow precise adjustment of the media flow, control elements are used for switching functions of cooler system for manual or automatic operation.
Temperature measurement: Temperature of water at the inlet
Temperature of water at the outlet to hot water tank
Temperature of ice water at the outlet
Temperature of the wort
Parameters: |
||
Technical specification | 1 stage | 2 stage |
Number of plates | 34 | 34 |
Number of plates in 1. st | - | 16 |
Number of plates in 2. st | - | 18 |
Inlet temperature of beer in 1. st | 90°C | 90°C |
Outlet temperature of beer in 1. st | 7°C | 25°C |
Inlet temperature of cold water | 1-2°C | 15°C |
Outlet temperature of cold water | 80-85°C | 65-70°C |
Inlet temperature of beer in 2. st | - | 25°C |
Outlet temperature of beer in 2. st | - | 7°C |
Inlet temperature of ice water | - | 0-1°C |
Outlet temperature of ice water | - | 3-5°C |
Aeration stone | AISI304 | AISI304 |
Manometer | 0 - 4 bar | 0 - 4 bar |
Thermometer Dixell XT11S | 3 pc | 4 pc |
Thermo reservoir + sensor | 3 pc | 4 pc |
Elektromagnetic valve for aeration | DN10 | DN10 |
Regulative valve of cold water flow | DN25 | DN25 |
Inlet of wort | DN40 | DN40 |
Outlet of wort | DN40 | DN40 |
Inlet of cold water | 1" | 1" |
Outlet of cold wate | 1" | 1" |
Inlet of ice water | - | 1" |
Outlet of ice water | - | 1" |
Dimensions: |
||
A - 1 200 mm | ||
B - 400 mm | ||
C - 280 mm |